De-Humidifier
STANDARD PRODUCT RANGE
- Available in 13 models, 100-10000 CMH supply air, 4kg hr to 64kg/hr moisture removal
- Standardproductsincludefullyfunctionalunitswith necessary safeties and electric relay based controls or optional PLC based controller
- Desiccant rotor technology removes water directly from the air
- Available with integrated pre and post cooling systems
- Utilize highly efficient solid desiccant fluted wheel
- Maximized dehumidified air flow capacities with very high and consistent performance levels
- PLC or electric relay based control choice
- G4 grade filters on both air streams
- Robust industrial duty structural frame and panel design
- Highly compact design-lowest foot print area
- The tailor made systems are delivered with:
High Quality
Hygienic Design
Easy Assemble on Site
Commissioning by our Skilled Service Engineers
Class -100 Mobile Trolley
Cleanliness | Class 100 / ISO CLASS 5 / M 3.5 AREA |
Velocity at Grill | 90 ± 10 FPM |
Material of Construction | S.S 304 |
HEPA Filter | Minipleated HEPA Filters down to 0.3mic. particulate at an efficiency of 99.999% (EU14) duly tested on DOP tested with SS-304 Protective Grill |
Intermediate Filter | Micro ‘V’ Filter down to 5mic. Particulate at an efficiency of 99% (EU9) enclosed in aluminum frame with epoxy sealing (Washable Type) |
Pre-Filters | Pre-Filter down to 10mic. Particulate at an efficiency of 95% (EU4) enclosed in aluminum frame with epoxy sealing (Washable Type) |
Blower Assembly | Dynamically and statically balanced motor and blower |
Side Panels | Both sideSS-304 Double Skinned PUF Insulated Panel |
Front Door | Do with Flexible PVC Strip Curtain |
Electrical | 1) On/Off Switch 2) Fluorescent Light 3) U V Light 4) Auxiliary Socket |
Pressure Gauge | Magnahelic Gaugeone is to check the pressure drop across the HEPA filter and other for pre & micro ‘V’ (intermediate) filters |
Powder supply | 230 V, 50Hz, Single Phase |
Documentation | DQ, IQ, OQ Test Certificate |
Mobile Tent
Mobile Type Clean Air Tent
Vertical Laminar Flow Mobile Type Air Tent allows operation in sterile and particle free conditions because of the continuous flushing of the working area by a unidirectional and vertical and ultra-filtered airflow, it assures a full product protection.
Design: Basic cabinet made from 1.2 mm thick GI with powder coated finish constructions with matt finish. Unit consists of HEPA filter plenum, each consists of a 0.3 micron HEPA filter, 10 micron Pre filters and Supply Air Blower etc., and suitable illumination and control switches etc will be provided.
Function: The system works based on two-stage air filtration. The fresh air from the local atmosphere is sucked by the blower through pre-filters and passed into the working area through HEPA filters. Particles retained at pre filters level will be 10 micron and at HEPA Filter level will be 0.3 micron.
Contaminated air from process area may be directly left into the local atmosphere or may be exhausted; this depends up on the nature contamination created during the process activity.
Suitable for maintaining a positive pressure inside; on lockable wheels; easily dissembled and reassembled type; all filters installed on top or side
Air Shower Unit
Cleanliness | : | ISO 8 |
Material of Construction | :
|
Main Structure do with MS Powder Coated / S.S. 304 construction
Inside Working Area : MS Powder Coated / S.S 304 Bottom do with Aluminum Checker Plate Both Side Entry / Exit Door : S.S / GI Powder Coated duly Double Skinned |
Velocity at Nozzle | : | 15 ± 5 M/S |
Blower Assembly | : | Statically and dynamically balanced Motor & Blower, designed for supply of sufficient capacity and static pressure to take care of airflow |
Doors | : | Automatic swing, micro-processor controlled electromagnetic inter locking doors with glass panels. (Comprising with Door Closure, ‘D’ Handle, Ball Bearing Hinges) |
HEPA Filter | : | HEPA Filters down to 0.3mic. particulate at an efficiency of 99.999% (H14) duly tested on PAO tested |
Make-up Air Filter | : | Pre-Filter down to 5mic. Particulate at an efficiency of 95% (EU5) enclosed in aluminum frame with epoxy sealing (Washable Type) |
Return Air Filter | : | Pre-Filter Filter down to 5mic. Particulate at an efficiency of 95% (EU5) enclosed in aluminum frame with epoxy sealing (Disposable Type) |
Nozzle | : | All Nozzles with S.S. 304 |
Door Interlocking | : | Door Opening with Solid State Electronic Inter Locking Mechanism |
Power supply | : | 440 V, 50Hz, Three Phase |
Operation Sequence | Detail of logic Sequence: | |
First Cycle of operation : – | ||
When D1 & D2 are Closed (Both Door are in locked condition)
Blower in off condition |
||
When D1 is Opened (Door D2 gets locked condition)
Blower in off condition |
||
When D1 is closed (Door D2 still in locked condition)
Blower will be on when both doors are in locked condition |
||
Blower motor (As per timer setting) gets off and then Door D2 gets opened / unlocked, D1 in locked condition | ||
Door D2 is closed condition | ||
Door D1 / D2 gets opened / unlocked | ||
At a time only one door can opened | ||
Emergency Stop/Unlock Button provided at Entry / Exit/ Inside chamber |
Dust Collector
PULSE JET DUST COLLECTOR
Pulse Jet Dust Collector, Construction as follows: Cylindrical fabric filter elements, enclosed in dust tight rectangle housing MOC :Main Body and support MS Powdercoated I D Fan : MS Powder coated Description: Fully automatic with self-cleaning pulse jet related accessories and solenoid valve program timer sets with required TEFC motor suitable for 3-phase high efficiency suction blower direct or v. Belt drive& Motor |
Modular Partition
“PROTECH” provides the vast variation of clean rooms wall and puf panels in the construction
in demand to board a range of modular cleanroom partitions application.
Design for pharmaceutical application that required a flush wall surface with radius corners for
ease of cleaning, modular false ceiling to bacterial and fungal growths.
Clean Room Panels:
Pharmaceuticals application required panel that can be washed constantly without separating
clean room partitions although design completes withstand continued cleaning and sanitization
with various chemicals to resist microbial and fungal development.
Intended to meets the particulars for Classes 100 to 100,000 (ISO 5 to ISO 8) condition. We are
manufacturers, exporters and suppliers of clean room partitions with wall, puf panel and modular
false ceiling in Ahmedabad India to worldwide with assured safety features. Also used primarily
in the microelectronic and nanotechnology businesses, these organizations is perfect for request
requiring bulk heading adaptability or conditions necessary non-outgassing, non-shedding and
hostile to static divider administrations.
Clean room puf Panels Consists of Following sub components: Clean room Windows, Coving,
3D Corner Pieces, 2D corner pieces.
Features:
- Completely Flush Panel System with Width: 50 mm, 80 mm, 100 mm
- Fully Integrated Aseptic Envelope
- Class 100 Compatible
- Integrated Flush Ceiling & Window Systems
- Various Protection: PUF/ Mineral Wool/ EPS/ Paper Honey Comb and PIR
- Sheet Thickness: 0.5/ 0.7/ 1.00 mm
- Panels Attachment: Aluminium connect with each other shape
- Prospect Panels Glossing: blush 6 mm harden glasses on all sides
- Door: PCGI Single and Double Steel lock establish constructions
- Coving: Aluminium separate fitting coving to avoid corner dust accumulation
Sampling / Dispensing Booth (RLAF Unit)
Cleanliness | Class 100 / ISO CLASS 5 / M 3.5 AREA |
Velocity at Grill | 90 ± 10 FPM |
Material of Construction | S.S 304 |
HEPA Filter | Minipleated HEPA Filters down to 0.3mic. particulate at an efficiency of 99.999% (EU14) duly tested on DOP tested with SS-304 Protective Grill |
Intermediate Filter | Micro ‘V’ Filter down to 5mic. Particulate at an efficiency of 99% (EU9) enclosed in aluminum frame with epoxy sealing (Washable Type) |
Pre-Filters | Pre-Filter down to 10mic. Particulate at an efficiency of 95% (EU4) enclosed in aluminum frame with epoxy sealing (Washable Type) |
Blower Assembly | Dynamically and statically balanced motor and blower |
Side Panels | Both sideSS-304 Double Skinned PUF Insulated Panel |
Front Door | Do with Flexible PVC Strip Curtain |
Electrical | 1) On/Off Switch 2) Fluorescent Light 3) U V Light 4) Auxiliary Socket |
Pressure Gauge | Magnahelic Gaugeone is to check the pressure drop across the HEPA filter and other for pre & micro ‘V’ (intermediate) filters |
Powder supply | 230 V, 50Hz, Single Phase |
Documentation | DQ, IQ, OQ Test Certificate |
Laminar Air Flow Unit
Cleanliness | : | Class 100 / ISO CLASS 5 | |
Flow Direction | : | HORIZONTAL / VERTICAL | |
Velocity at Grill | : | 90 ± 20 FPM (0.45 ± 20 m/sec) | |
Material of Construction | : | External & Internal part with : MS Powder Coated / SS 304
Working top with SS-304 |
|
HEPA Filter | : | Minipleated HEPA Filters down to 0.3mic. particulate at an efficiency of 99.997% (EU14) duly tested on DOP tested | |
Pre-Filters | : | Pre-Filter down to 5mic. Particulate at an efficiency of 95% (EU7) enclosed in aluminum frame with epoxy sealing (Washable Type) | |
Side Wall | : | Do with Glass | |
Accessories | : | DOP Port | |
Blower Assembly | : | Dynamically and statically balanced blower and motor | |
Electrical | : | 1) On/Off Panel (BL / FL / UV)
2) FL Light 3) U V Light |
|
Pressure Measurement | : | Magnehalic Gauge to check the pressure drop across the HEPA filter | |
Power supply | : | 230 V, 50Hz, Single Phase | |
Documentation | : | DQ, IQ, OQ Report |
AHU Filter
Sr.
No. |
Item Description |
A. | AIR HANDLING UNIT (AHU) |
Type : Floor Mount / Wall Mount / Ceiling Mount | |
Design : Draw Through | |
Frame Work : Non Thermal Break / Thermal Break | |
Panem MOC : Double Skinned / single Skinned | |
Base Frame : GI Skid / MS Channel | |
Outer Sheet : 0.6 mm Powder Coated | |
Inner Sheet : 0.6 mm Plain GI | |
Panel Thick : 25 mm / 50 mm | |
Insulation : Injected PUF @ 40+/- 5 Kg/m3 | |
Type of Drive : V-Belt Driven / Direct Drive | |
Types of Fan : Backward Curved | |
Fan Make : Krugar / Nicotra | |
Motor Make : ABB / CGL / Bharat Bijali | |
Filtration Stage : EU4, EU5 | |
Drain Tray : SS-304 duly Insulation | |
Nos. of Damper : SA, RA, FA | |
Types of Damper : Aluminum | |
Types of Zone : | |
> Mixing Chamber | |
> Pre-Filter Chamber with EU4 Filter | |
> Cooling Coil Section with DX type cooling coil | |
> Heater Section | |
> Blower Section | |
> Fine Filter Chamber with EU7 Filter | |
> Supply Plenum with SA Damper | |
|
AHU CAPACITY : 500 CFM to 50000 CFM |